Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 215
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38626902

RESUMO

BACKGROUND: The benefits of minimally invasive techniques in cardiac surgery remain poorly defined. We evaluated the short- and mid-term outcomes after surgical aortic valve replacement through partial upper versus complete median sternotomy (MS) in a large, German multicenter cohort. METHODS: A total of 2,929 patients underwent isolated surgical aortic valve replacement via partial upper sternotomy (PUS, n = 1,764) or MS (n = 1,165) at nine participating heart centers between 2016 and 2020. After propensity-score matching, 1,990 patients were eligible for analysis. The primary end point was major adverse cardiac and cerebrovascular events (MACCE), a composite of death, myocardial infarction, and stroke at 30 days and in follow-up, up to 5 years. Secondary end points were acute kidney injury, length of hospital stay, transfusions, deep sternal wound infection, Dressler's syndrome, rehospitalization, and conversion to sternotomy. RESULTS: Unadjusted MACCE rates were significantly lower in the PUS group both at 30 days (p = 0.02) and in 5-year follow-up (p = 0.01). However, after propensity-score matching, differences between the groups were no more statistically significant: MACCE rates were 3.9% (PUS) versus 5.4% (MS, p = 0.14) at 30 days, and 9.9 versus 11.3% in 5-year follow-up (p = 0.36). In the minimally invasive group, length of intensive care unit (ICU) stay was shorter (p = 0.03), Dressler's syndrome occurred less frequently (p = 0.006), and the rate of rehospitalization was reduced significantly (p < 0.001). There were 3.8% conversions to full sternotomy. CONCLUSION: In a large, German multicenter cohort, MACCE rates were comparable in surgical aortic valve replacement through partial upper and complete sternotomies. Shorter ICU stay and lower rates of Dressler's syndrome and rehospitalization were in favor of the partial sternotomy group.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38626901

RESUMO

BACKGROUND: We aimed to investigate the in-hospital and midterm outcomes of patients undergoing ascending aortic replacement (AAR) through a partial or a full sternotomy approach through a propensity matching analysis. METHODS: We retrospectively included all patients (n = 167) who underwent elective AAR in our institution between 2013 and 2020. The study population was divided into two groups according to the surgical access (40 patient in the partial sternotomy or "PS" group and 127 in the full sternotomy or "FS" group). Due to the significant differences between the groups, a propensity matching of 1:3 was applied. In-hospital complications, survival, and reoperation at follow-up were investigated. RESULTS: The PS group showed higher cross-clamp and cardiopulmonary bypass times than the FS group (94.2 vs. 83 minutes and 164.2 vs. 126.8 minutes, respectively). Moreover, the postoperative ventilation time was significantly higher in the PS group, but it did not affect the length of stay in the intensive care unit (ICU). The incidences of bleeding, stroke, and mortality were comparable between the two groups (11 vs. 3%, 3 vs. 6%, and 5 vs. 3%, respectively). After a median follow-up of 2 ± 1.98 years, the Kaplan-Meier analysis showed no significant differences between the two groups (log-rank, p = 0.17) in terms of survival. CONCLUSION: The surgical ascending aorta replacement through a partial sternotomy is associated with longer operative times, but this does not affect the early as well as the long-term follow-up.

3.
J Clin Med ; 13(6)2024 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-38541805

RESUMO

Background: An unexplained condition that follows transcatheter aortic valve implantation (TAVI) is platelet count reduction (PR). According to published research, patients with balloon-expandable valves (BEVs) had a greater PR than those with self-expandable valves (SEVs). Objectives: The purpose of this study was to investigate the incidence and clinical effects of PR following TAVI. Methods: In total, 1.122 adult TAVI patients were enrolled. Propensity score matching was carried out in a 1:1 ratio between patients with BEVs and those with SEVs. The analysis included changes in platelet count, in-hospital mortality, and early postoperative adverse events. Results: Notably, 632 patients were matched (BEV:316; SEV:316). All patients' post-procedural platelet counts changed according to a parabolic curve, using a mixed regression model for repeated analyses (estimate = -0.931; standard error = 0.421; p = 0.027). The platelet count varied comparably in patients with BEVs and SEVs (estimate = -4.276, standard error = 4.760, p = 0.369). The average time for obtaining the nadir platelet count value was three days after implantation (BEV: 146 (108-181) vs. SEV: 149 (120-186); p = 0.142). Overall, 14.6% of patients (92/632) had post-procedural platelet count <100,000/µL. There was no difference between the two prosthesis types (BEV:51/316; SEV:41/316; p = 0.266). Thrombocytopenia was found to be significantly linked to blood product transfusions, lengthier stays in the intensive care unit and hospital, and in-hospital mortality. Conclusions: TAVI, irrespective of the type of implanted valve, is linked to a significant but temporary PR. Thrombocytopenia increases the risk of serious complications and in-hospital death in TAVI patients. To explore and clarify the causes and associated effects, further prospective research is necessary.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38327179

RESUMO

BACKGROUND AND AIMS: Mechanical complications (MCs) are rare but potentially fatal sequelae of acute myocardial infarction (AMI). Surgery, though challenging, is considered the treatment of choice. The authors sought to study early and long-term results of patients undergoing surgical treatment for post-AMI MCs. METHODS: Patients undergone surgical treatment for post-infarction MCs between 2001 through 2019 in 27 centers worldwide were retrieved from the database of CAUTION study. In-hospital and long-term mortality were the primary outcomes. Cox proportional hazards regression models were used to determine independent factors associated with overall mortality. RESULTS: The study included 720 patients. The median age was 70.0 [62.0-77.0] years, with a male predominance (64.6%). The most common MC encountered was ventricular septal rupture (VSR) (59.4%). Cardiogenic shock was seen on presentation in 56.1% of patients. In-hospital mortality rate was 37.4%; in more than 50% of cases, the cause of death was low cardiac output syndrome (LCOS). Late mortality occurred in 133 patients, with a median follow-up of 4.4 [1.0-8.6] years. Overall survival at 1, 5 and 10 years was 54.0%, 48.1% and 41.0%, respectively. Older age (p < 0.001) and postoperative LCOS (p < 0.001) were independent predictors of overall mortality. For hospital survivors, 10-year survival was 65.7% and was significant higher for patients with VSR than those with papillary muscle rupture (long-rank P = 0.022). CONCLUSIONS: Contemporary data from a multicenter cohort study show that surgical treatment for post-AMI MCs continues to be associated with high in-hospital mortality rates. However, long-term survival in patients surviving the immediate postoperative period is encouraging.Trial registration number: NCT03848429.

5.
Eur J Cardiothorac Surg ; 65(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38212996

RESUMO

OBJECTIVES: In the last decades, 4 different scores for the prediction of mortality following surgery for type A acute aortic dissection (TAAD) were proposed. We aimed to validate these scores in a large external multicentre cohort. METHODS: We retrospectively analysed patients who underwent surgery for TAAD between 2000 and 2020. Patients were enrolled from 10 centres from 2 European countries. Outcomes were the early (30-day and/or in-hospital) and 1-year mortality. Discrimination, calibration and observed/expected (O/E) ratio were evaluated. RESULTS: A total of 1895 patients (31.7% females, mean age 63.72 ± 12.8 years) were included in the study. Thirty-day mortality and in-hospital mortality were 21.7% (n = 412) and 22.5% (n = 427) respectively. The German Registry of Acute Aortic Dissection Type A (GERAADA) score shows to have the best discrimination [area under the curve (AUC) 0.671 and 0.672] in predicting as well the early and the 1-year mortality, followed by the International Registry of Acute Aortic Dissection (IRAD) model 1 (AUC 0.658 and 0.672), the Centofanti (AUC 0.645 and 0.66) and the UK aortic score (AUC 0.549 and 0.563). According to Hosmer-Lemeshow and Brier tests, the IRAD model I and GERAADA, respectively, were well calibrated for the early mortality, while the GERAADA and Centofanti for the 1-year mortality. The O/E analysis showed a marked underestimation for patients labelled as low-risk for UK aortic score and IRAD model I for both outcomes. CONCLUSIONS: The GERAADA score showed the best performance in comparison with other scores. However, none of them achieved together a fair discrimination and a good calibration for predicting either the early or the 1-year mortality.


Assuntos
Dissecção Aórtica , Azidas , Desoxiglucose/análogos & derivados , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Estudos Retrospectivos , Dissecção Aórtica/cirurgia , Mortalidade Hospitalar , Europa (Continente) , Sistema de Registros , Fatores de Risco , Resultado do Tratamento
6.
J Clin Med ; 12(23)2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-38068466

RESUMO

Background: Platelet count reduction (PR) is a common but unclear phenomenon that occurs after aortic bioprosthesis valve implantation (bio-AVR). This study aimed to investigate the occurrence and clinical impact of PR in patients receiving stented, rapid deployment (RDV), or stentless bioprostheses. Methods: 1233 adult bio-AVR patients were enrolled. Platelet count variation, early post-operative adverse events, and in-hospital mortality were analysed. Results: 944 patients received a stented valve, an RDV was implanted in 218 patients, and 71 patients had a stentless bioprosthesis. In all groups, the platelet count at discharge was lower than the baseline values (p < 0.001). The percentage of PR was 27% in the stented group, 56% in the RDV group, and 55% in the stentless group. A higher platelet reduction, reaching the minimum platelet value, was observed in the RDV (mean: -30.84, standard error (SE): 5.91, p < 0.001) and stentless (mean: 22.54, SE: 9.10, p = 0.03) groups compared to the stented group. A greater PR occurred as the size of the bioprosthesis increased in RDV (p = 0.01), while platelet count variation was not directly proportional to the stented bioprosthesis size (p < 0.001). PR was not affected by cardiopulmonary bypass (mean: -0.00, SE: 0.001, p = 0.635) or cross-clamp (mean: -0.00, SE: 0.002, p = 0.051) times in any of the groups. RDV subjects experienced more in-hospital adverse events. PR was found to be associated with ischemic strokes in the overall population. Conclusions: Bio-AVR is associated with significant but transient PR. RDV patients more likely experience significant PR and related adverse clinical events. PR is associated with ischemic strokes, regardless of the bioprosthesis type.

7.
Artigo em Inglês | MEDLINE | ID: mdl-38109676

RESUMO

OBJECTIVES: Post-acute myocardial infarction mechanical complications (post-AMI MCs) represent rare but life-threatening conditions, including free-wall rupture, ventricular septal rupture and papillary muscle rupture. During the coronavirus disease-19 (COVID-19) pandemic, an overwhelming pressure on healthcare systems led to delayed and potentially suboptimal treatments for time-dependent conditions. As AMI-related hospitalizations decreased, limited information is available whether higher rates of post-AMI MCs and related deaths occurred in this setting. This study was aimed to assess how COVID-19 in Europe has impacted the incidence, treatment and outcome of MCs. METHODS: The CAUTION-COVID19 study is a multicentre retrospective study collecting 175 patients with post-AMI MCs in 18 centres from 6 European countries, aimed to compare the incidence of such events, related patients' characteristics, and outcomes, between the first year of pandemic and the 2 previous years. RESULTS: A non-significant increase in MCs was observed [odds ratio (OR) = 1.15, 95% confidence interval (CI) 0.85-1.57; P = 0.364], with stronger growth in ventricular septal rupture diagnoses (OR = 1.43, 95% CI 0.95-2.18; P = 0.090). No significant differences in treatment types and mortality were found between the 2 periods. In-hospital mortality was 50.9% and was higher for conservatively managed cases (90.9%) and lower for surgical patients (44.0%). Patients admitted during COVID-19 more frequently had late-presenting infarction (OR = 2.47, 95% CI 1.24-4.92; P = 0.010), more stable conditions (OR = 2.61, 95% CI 1.27-5.35; P = 0.009) and higher EuroSCORE II (OR = 1.04, 95% CI 1.01-1.06; P = 0.006). CONCLUSIONS: A non-significant increase in MCs incidence occurred during the first year of COVID-19, characterized by a significantly higher rate of late-presenting infarction, stable conditions and EuroSCORE-II if compared to pre-pandemic data, without affecting treatment and mortality.

8.
Eur Heart J Open ; 3(5): oead091, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37840585

RESUMO

Aims: Many historical and recent reports showed that post-infarction ventricular septal rupture (VSR) represents a life-threatening condition and the strategy to optimally manage it remains undefined. Therefore, disparate treatment policies among different centres with variable results are often described. We analysed data from European centres to capture the current clinical practice in VSR management. Methods and results: Thirty-nine centres belonging to eight European countries participated in a survey, filling a digital form of 38 questions from April to October 2022, to collect information about all the aspects of VSR treatment. Most centres encounter 1-5 VSR cases/year. Surgery remains the treatment of choice over percutaneous closure (71.8% vs. 28.2%). A delayed repair represents the preferred approach (87.2%). Haemodynamic conditions influence the management in almost all centres, although some try to achieve patients stabilization and delayed surgery even in cardiogenic shock. Although 33.3% of centres do not perform coronarography in unstable patients, revascularization approaches are widely variable. Most centres adopt mechanical circulatory support (MCS), mostly extracorporeal membrane oxygenation, especially pre-operatively to stabilize patients and achieve delayed repair. Post-operatively, such MCS are more often adopted in patients with ventricular dysfunction. Conclusion: In real-life, delayed surgery, regardless of the haemodynamic conditions, is the preferred strategy for VSR management in Europe. Extracorporeal membrane oxygenation is becoming the most frequently adopted MCS as bridge-to-operation. This survey provides a useful background to develop dedicated, prospective studies to strengthen the current evidence on VSR treatment and to help improving its currently unsatisfactory outcomes.

9.
J Clin Med ; 12(17)2023 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-37685547

RESUMO

BACKGROUND: predicting the 1-year survival of patients undergoing transcatheter aortic valve implantation (TAVI) is indispensable for managing safe early discharge strategies and resource optimization. METHODS: Routinely acquired data (134 variables) were used from 629 patients, who underwent transfemoral TAVI from 2012 up to 2018. Support vector machines, neuronal networks, random forests, nearest neighbour and Bayes models were used with new, previously unseen patients to predict 1-year mortality in TAVI patients. A genetic variable selection algorithm identified a set of predictor variables with high predictive power. RESULTS: Univariate analyses revealed 19 variables (clinical, laboratory, echocardiographic, computed tomographic and ECG) that significantly influence 1-year survival. Before applying the reject option, the model performances in terms of negative predictive value (NPV) and positive predictive value (PPV) were similar between all models. After applying the reject option, the random forest model identified a subcohort showing a negative predictive value of 96% (positive predictive value = 92%, accuracy = 96%). CONCLUSIONS: Our model can predict the 1-year survival with very high negative and sufficiently high positive predictive value, with very high accuracy. The "reject option" allows a high performance and harmonic integration of machine learning in the clinical decision process.

10.
Surgery ; 174(5): 1153-1160, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37714757

RESUMO

BACKGROUND: Recent randomized controlled trials showed comparable short-term outcomes of transcatheter aortic valve implantation versus surgical aortic valve replacement in intermediate and low-risk patients. However, independent studies comparing transcatheter aortic valve implantation results versus surgical aortic valve replacement at 5 years showed worsening outcomes in patients treated with transcatheter aortic valve implantation. The aim of this study was to analyze mid- to long-term outcomes of patients with isolated aortic stenosis and an intermediate-risk profile who underwent aortic valve replacement using a sutureless valve versus transcatheter aortic valve implantation. METHODS: This retrospective multi-institutional European study investigated 2,123 consecutive patients with isolated aortic stenosis at intermediate risk profile treated with sutureless aortic valve replacement (824 patients) or transcatheter aortic valve implantation (1,299 patients) from 2013 to 2020. After 1:1 propensity score matching, 2 balanced groups of 517 patients were obtained. Primary endpoints were as follows: 30 days, late all-cause, and cardiac-related mortality. Secondary endpoints included major adverse cardiocerebrovascular events (all-cause death, stroke/transient ischemic attack, endocarditis, reoperation, permanent pacemaker implantation, and paravalvular leak grade ≥2). RESULTS: Median follow-up was 4.3 years (interquartile range 1.1-7.4 years). Primary endpoints were as follows-30-day mortality sutureless aortic valve replacement: 2.13% versus transcatheter aortic valve implantation: 4.64% (P = .026), all-cause mortality sutureless aortic valve replacement: 36.7% ± 7.8% vs transcatheter aortic valve implantation: 41.8% ± 8.2% (P = .023), and cardiac-related mortality sutureless aortic valve replacement: 10.2% ± 2.8% vs transcatheter aortic valve implantation: 19.2% ± 3.5%;(P = .00043) at follow-up. Secondary endpoints were as follows-major adverse cardiocerebrovascular events in the sutureless aortic valve replacement group: 47.2% ± 9.0% versus transcatheter aortic valve implantation: 57.3% ± 7.5% (P < .001). In particular, the incidence of permanent pacemaker implantation (sutureless aortic valve replacement: 6.38% versus transcatheter aortic valve implantation: 11.8% [P = .002]) and paravalvular leak ≥2 (sutureless aortic valve replacement: 0.97% versus transcatheter aortic valve implantation: 4.84% [P = .001]) was significantly higher in transcatheter aortic valve implantation group. At Multivariable Cox regression analysis, paravalvular leak ≥2 (hazard ratio: 1.63%; 95% confidence interval: 1.06-2.53, P = .042) and permanent pacemaker implantation (hazard ratio: 1.49%; 95% confidence interval: 1.02-2.20, P = .039) were identified as predictors of mortality. CONCLUSION: Sutureless aortic valve replacement showed a significantly lower incidence of all-cause mortality, cardiac-related death, permanent pacemaker implantation, and paravalvular leak than transcatheter aortic valve implantation. Moreover, permanent pacemaker implantation and paravalvular leak negatively affected survival in patients treated for isolated aortic stenosis.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Estudos Retrospectivos , Fatores de Risco , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
12.
J Clin Med ; 12(12)2023 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-37373738

RESUMO

BACKGROUND: Recent trials showed that TAVI is neither inferior nor superior to surgical aortic valve replacement. The aim of this study was to evaluate the outcomes of Sutureless and Rapid Deployment Valves (SuRD-AVR) when compared to TAVI in low surgical risk patients with isolated aortic stenosis. METHODS: Data from five European Centers were retrospectively collected. We included 1306 consecutive patients at low surgical risk (EUROSCORE II < 4) who underwent aortic valve replacement by means of SuRD-AVR (n = 636) or TAVI (n = 670) from 2014 to 2019. A 1:1 nearest-neighbor propensity-score was performed, and two balanced groups of 346 patients each were obtained. The primary endpoints of the study were: 30-day mortality and 5-year overall survival. The secondary endpoint was 5-year survival freedom from major adverse cardiovascular and cerebrovascular events (MACCEs). RESULTS: Thirty-day mortality was similar between the two groups (SuRD-AVR:1.7%, TAVI:2.0%, p = 0.779), while the TAVI group showed a significantly lower 5-year overall survival and survival freedom from MACCEs (5-year matched overall survival: SuRD-AVR: 78.5%, TAVI: 62.9%, p = 0.039; 5-year matched freedom from MACCEs: SuRD-AVR: 64.6%, TAVI: 48.7%, p = 0.004). The incidence of postoperative permanent pacemaker implantation (PPI) and paravalvular leak grade ≥ 2 (PVL) were higher in the TAVI group. Multivariate Cox Regression analysis identified PPI as an independent predictor for mortality. CONCLUSIONS: TAVI patients had a significantly lower five-year survival and survival freedom from MACCEs with a higher rate of PPI and PVL ≥ 2 when compared to SuRD-AVR.

13.
Int J Cardiol ; 385: 8-15, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-37209782

RESUMO

OBJECTIVE: Our aim was to analyse whether prophylactic preoperative intraaortic balloon pump (IABP) improves outcomes in hemodynamically stable patients with low left ventricular ejection fraction (LVEF ≤30%) undergoing elective myocardial revascularization (CABG) using cardiopulmonary bypass (CPB). Secondary aim was to identify the predictors for low cardiac output syndrome (LCOS). METHODS: Prospectively collected data of 207 consecutive patients with LVEF ≤30% undergoing elective isolated CABG with CPB from 01/2009 to 12/2019, 136 with and 71 patients without IABP, were retrieved retrospectively. Patients with prophylactic IABP were matched 1:1 with patients without IABP by a propensity score matching. Stepwise logistic regression was conducted to identify predictors of postoperative LCOS in the propensity-matched cohort. P value ≤0.05 was considered significant. RESULTS: Reduced postoperative LCOS (9.9% vs. 26.8%, P = 0.017) was observed in patients receiving prophylactic IABP. Stepwise logistic regression identified preoperative IABP as preventive factor for postoperative LCOS [Odds Ratio (OR) 0.19,95% Confidence Interval (CI), 0.06-0.55, P = 0.004]. The need of vasoactive and inotropic support was lower in patients with prophylactic IABP at 24, 48 and 72 h after surgery (12.3 [8.2-18.6] vs. 22.2 [14.4-28.8], P < 0.001, 7.7 [3.3-12.3] vs.16.3 [8.9-27.8], P < 0.001 and 2.4 [0-7] vs. 11.5 [3.1-26], P < 0.001, respectively). The patients in both groups did not differ in terms of in-hospital mortality (7.0% vs. 9.9%, P = 0.763). There were no major IABP-related complications. CONCLUSIONS: Elective patients with left ventricular ejection fraction ≤30% undergoing CABG with CPB and prophylactic IABP insertion had less low cardiac output syndrome and similar in-hospital mortality.


Assuntos
Baixo Débito Cardíaco , Disfunção Ventricular Esquerda , Humanos , Volume Sistólico , Baixo Débito Cardíaco/etiologia , Ponte Cardiopulmonar/efeitos adversos , Estudos Retrospectivos , Função Ventricular Esquerda , Tempo de Internação , Ponte de Artéria Coronária , Disfunção Ventricular Esquerda/etiologia , Balão Intra-Aórtico , Resultado do Tratamento
14.
Artif Organs ; 47(8): 1386-1394, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37039965

RESUMO

BACKGROUND: Post-acute myocardial infarction papillary muscle rupture (post-AMI PMR) may present variable clinical scenarios and degree of emergency due to result of cardiogenic shock. Veno-arterial extracorporeal life support (V-A ECLS) has been proposed to improve extremely poor pre- or postoperative conditions. Information in this respect is scarce. METHODS: From the CAUTION (meChanical complicAtion of acUte myocardial infarcTion: an InternatiOnal multiceNter cohort study) database (16 different Centers, data from 2001 to 2018), we extracted adult patients who were surgically treated for post-AMI PMR and underwent pre- or/and postoperative V-A ECLS support. The end-points of this study were in-hospital survival and ECLS complications. RESULTS: From a total of 214 post-AMI PMR patients submitted to surgery, V-A ECLS was instituted in 23 (11%) patients. The median age was 61.7 years (range 46-81 years). Preoperatively, ECLS was commenced in 10 patients (43.5%), whereas intra/postoperative in the remaining 13. The most common V-A ECLS indication was post-cardiotomy shock, followed by preoperative cardiogenic shock and cardiac arrest. The median duration of V-A ECLS was 4 days. V-A ECLS complications occurred in more than half of the patients. Overall, in-hospital mortality was 39.2% (9/23), compared to 22% (42/219) for the non-ECLS group. CONCLUSIONS: In post-AMI PMR patients, V-A ECLS was used in almost 10% of the patients either to promote bridge to surgery or as postoperative support. Further investigations are required to better evaluate a potential for increased use and its effects of V-A ECLS in such a context based on the still high perioperative mortality.


Assuntos
Cardiomiopatias , Oxigenação por Membrana Extracorpórea , Doenças das Valvas Cardíacas , Infarto do Miocárdio , Adulto , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Oxigenação por Membrana Extracorpórea/métodos , Choque Cardiogênico/etiologia , Choque Cardiogênico/cirurgia , Estudos de Coortes , Músculos Papilares/cirurgia , Infarto do Miocárdio/complicações , Cardiomiopatias/complicações , Doenças das Valvas Cardíacas/complicações
15.
Infection ; 51(5): 1523-1530, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37024627

RESUMO

PURPOSE: The spectrum of causative organisms in infective endocarditis (IE) has changed significantly in the last decades. Reliable pathogen detection is crucial for appropriate antimicrobial therapy for IE. The aim of the study was to evaluate the diagnostic value of microbiological methods for detecting the causative microorganism of IE and to analyze the spectrum of pathogens. METHODS: A total of 224 cases (211 unique patients, some with multiple surgeries) were included into this retrospective study. Patients were diagnosed with IE according to the modified Duke criteria from January 2016 to July 2021 and underwent heart valve surgery in a tertiary hospital. Pathogen detection was performed by blood culture, microbiological culture and 16S rDNA PCR of explanted heart valve material. RESULTS: A causative pathogen of IE was detected in 95.5% (n = 214) of cases. Blood cultures were positive in 83.3%, while a pathogen in the examined heart valve samples was identified in 32.6% by culture and in 88.2% by 16S rDNA PCR. A microorganism was identified by 16S rDNA PCR in 61.1% of blood culture negative cases but only in 19.4% by heart valve culture. The most common pathogens were Staphylococcus aureus (27%), viridans group streptococci (20%), enterococci (19%) and coagulase-negative staphylococci (CoNS 8%). Cutibacterium acnes (7%) was detected in prosthetic valve IE cases only. CONCLUSION: Blood culture as a comparatively non-invasive and straightforward technique remains an important and reliable method for initial detection of the causative organism in IE. Diagnostic stewardship programs should broadly emphasize proper collection of blood cultures, particularly sampling prior to any antibiotic treatment. Additionally, molecular testing using 16S rDNA tissue PCR can be used with culture techniques to increase the diagnostic yield, especially in the case of a negative blood culture.


Assuntos
Endocardite Bacteriana , Endocardite , Humanos , Estudos Retrospectivos , Bactérias/genética , RNA Ribossômico 16S/genética , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/tratamento farmacológico , Endocardite Bacteriana/microbiologia , Endocardite/diagnóstico , Endocardite/cirurgia , Endocardite/microbiologia , DNA Ribossômico/genética
17.
Artigo em Inglês | MEDLINE | ID: mdl-36914161

RESUMO

BACKGROUND: We aimed to evaluate the impact of membranous interventricular septum (MIS) length and calcifications of the native aortic valve (AV), via preoperative multidetector computed tomography (MDCT) scan, on postoperative atrioventricular block III (AVB/AVB III) and permanent pacemaker implantation in surgical aortic valve replacement (SAVR). METHODS: We retrospectively analyzed preoperative contrast-enhanced MDCT scans and procedural outcomes of patients affected by AV stenosis who underwent SAVR at our center (June 2016-December 2019). The study population was divided into two groups (AVB and non-AVB), and variables were compared with a Mann-Whitney's U-test or chi-square test. Data were further analyzed using point biserial correlation and logistic regression. RESULTS: A total of 155 (38% female) patients (mean age of 71.2 ± 6 years) were enrolled in our study: conventional stented bioprosthesis (N = 99) and sutureless prosthesis (N = 56) were implanted. A postoperative AVB III was observed in 11 patients (7.1%). AVB patients had significant greater calcifications in left coronary cusp (LCC) -AV (non-AVB = 181.0 mm3 [82.7-316.9] vs. AVB = 424.8 mm3 [115.9-563.2], p = 0.044), LCC left ventricular outflow tract (LVOT) (non-AVB = 2.1 mm3 [0-20.1] vs. AVB = 26.0 mm3 [0.1-138.0], p = 0.048), right coronary cusp (RCC) -LVOT (non-AVB = 0 mm3 [0-3.5] vs. AVB = 2.8 mm3 [0-29.0], p = 0.039), and consequently in total LVOT (non-AVB = 2.1 mm3 [0-20.1] vs. AVB = 26.0 mm3 [0.1-138.0], p = 0.02), while their MIS was significantly shorter than in non-AVB patients (non-AVB = 11.3 mm [9.9-13.4] vs. AVB = 9.44 mm [6.98-10.5]; p=0.014)). Partially, these group differences correlated positively (LCC -AV, r = 0.201, p = 0.012; RCC -LVOT, r = 0.283, p ≤ 0.001) or negatively (MIS length, r = -0.202, p = 0.008) with new-onset AVB III. CONCLUSION: We recommend including an MDCT in preoperative diagnostic testing for all patients undergoing surgical AVR for further risk stratification.

18.
Artigo em Inglês | MEDLINE | ID: mdl-36858846

RESUMO

OBJECTIVE: To assess the mid-term clinical outcomes, hemodynamics, left ventricular (LV) mass regression, and structural valve deterioration (SVD) in patients implanted with the Perceval aortic sutureless valve across valve sizes. METHODS: Data were obtained from a multicenter European trial and a US Investigational Device Exemption trial. Echocardiography data were analyzed by an echocardiography core lab. A mixed-effects regression model was used to assess relationships between hemodynamic outcomes, time from the procedure, and valve sizes. The Valve Academic Research Consortium (VARC)-3 definition for bioprosthetic valve failure was applied. RESULTS: A Perceval sutureless valve was implanted in 970 patients. The median patient age was 77.8 years, 57.2% were female, the median Society of Thoracic Surgeons predicated risk of mortality was 3.3% (range, 2.1%-6.2%), and 33.4% had a concomitant procedure. The median clinical follow-up was 45.7 months (range, 28.2-76.1 months). Small and medium valves were implanted more commonly in women than in men (16.9% vs 1.9% for small and 55.1% vs 19.5% for medium; P < .001). The mean aortic valve gradients decreased significantly postimplantation and remained stable across all valve sizes throughout the follow-up period. All patients were free from severe patient-prosthesis mismatch (with an effective orifice area/m2 of >0.8). Significant LV mass regression was documented regardless valve sizes, plateaued at -9.1% at 5 years. Freedom from SVD and reintervention were 95.2% and 96.3%, respectively, at 5 years and were independent of implanted valve size (P = .22). The VARC-3 stage 3 bioprosthetic valve failure rate was low, 2.8% at 5 years. CONCLUSIONS: The Perceval valve demonstrated low and stable mean gradients, significant LV mass regression, and low SVD and reintervention rates across all valve sizes.

19.
Artigo em Inglês | MEDLINE | ID: mdl-36802263

RESUMO

OBJECTIVES: Sepsis caused by infective endocarditis (IE), due to Staphylococcus aureus, is associated with significant morbidity and mortality. Blood purification using haemoadsorption (HA) may attenuate the inflammatory response. We investigated the effect of intraoperative HA on postoperative outcomes in S. aureus IE. METHODS: Patients with confirmed S. aureus IE undergoing cardiac surgery were included in a dual-centre study between January 2015 and March 2022. Patients treated with intraoperative HA (HA group) were compared to patients not treated with HA (control group). The primary outcome was vasoactive-inotropic score within the first 72 h postoperatively and secondary outcomes were sepsis-related mortality (SEPSIS-3 definition) and overall mortality at 30 and 90 days. RESULTS: No differences in baseline characteristics were observed between groups (haemoadsorption group, n = 75, control group, n = 55). Significantly decreased vasoactive-inotropic score was observed in the haemoadsorption group at all time points [6 h: 6.0 (0-17) vs 17 (3-47), P = 0.0014; 12 h: 2 (0-8.3) vs 5.9 (0-37), P = 0.0138; 24 h: 0 (0-5) vs 4.9 (0-23), P = 0.0064; 48 h: 0 (0-2.1) vs 0.1 (0-13), P = 0.0192; 72 h: 0 (0) vs 0 (0-5), P = 0.0014]. Importantly, sepsis-related mortality (8.0% vs 22.8%, P = 0.02) and 30-day (17.3% vs 32.7%, P = 0.03) and 90-day overall mortality (21.3% vs 40%, P = 0.03) were also significantly lower with haemoadsorption. CONCLUSIONS: Intraoperative HA during cardiac surgery for S. aureus IE was associated with significantly lower postoperative vasopressor and inotropic requirements and resulted in lower sepsis-related and overall 30- and 90-day mortality. In this high-risk population, improved postoperative haemodynamic stabilization by intraoperative HA appears to improve survival and should be further tested in future randomized trials.

20.
Thorac Cardiovasc Surg ; 71(7): 557-565, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36257545

RESUMO

OBJECTIVES: The aim of this study was to investigate the need for postoperative permanent pacemaker implantation (PPI) following sutureless and rapid-deployment aortic valve replacement (SuRD-AVR) in the context of a progress report from a large multicenter international registry (SURD-IR). METHODS: We retrospectively analyzed 4,166 patients who underwent SuRD-AVR between 2008 and 2019. The primary outcome was the need for PPI before discharge. The study population was analyzed separately according to the implanted prostheses (Su cohort and RD cohort). Each cohort was divided into two groups based on the operation date: an early group ("EG" = 2008-2016) and a late group ("LG" = 2017-2019). RESULTS: The rate of PPI decreased significantly in the Su cohort over time (EG = 10.8% vs LG = 6.3%, p < 0.001). In the Su cohort, a decrease in age, risk profile, and incidence of bicuspid aortic valve, increased use of anterior right thoracotomy, reduction of cardiopulmonary bypass time and of associated procedures, and more frequent use of smaller prostheses were observed over time. In the RD cohort, the rate of PPI was stable over time (EG = 8.8% vs LG = 9.3%, p = 0.8). In this cohort, a younger age, lower risk profile, and higher incidence of concomitant septal myectomy were observed over time. CONCLUSION: Our analysis showed a significant decrease in the PPI rate in patients who underwent Su-AVR over time. Patient selection as well as surgical improvements and a more accurate sizing could be correlated with this phenomenon. The RD cohort revealed no significant differences either in patient's characteristics or in PPI rate between the two time periods.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Procedimentos Cirúrgicos sem Sutura , Humanos , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Estudos Retrospectivos , Relatório de Pesquisa , Resultado do Tratamento , Desenho de Prótese , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Procedimentos Cirúrgicos sem Sutura/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...